Archive for February, 2007



Hydrogen Tap 1 (more questions) #4 - Hydrogen Auto Videos

Wednesday 28 February 2007 @ 6:34 pm

Hydrogen Tap 1 is working with colder water and less power


, , , , , ,




Hydrogen Tap 1 Series 2 (Output Test Tap Water Only) # 27 - Hydrogen Auto Videos

Wednesday 28 February 2007 @ 6:32 am

This is the test of the Series 2 unit for leaks and gas output using only tap water. The test runs for almost eight minutes and verifies that the unit puts out a constant amount of gas and keeps a steady amp reading. The test is being conducted with ½ inch tube with output into a water pitcher to observe the gas flow. The amp reading is below 15 and the voltage is being kept steady using two charging unites. This unit will be installed into the car between the air filter and the engine. Although the unit is performing well more likely than not I will change the plates out for 9 inch plates before going to the Series 3.


, , , , , , ,




Hydrogen Tap 1 Series 3(Plates In Plastic Tube) #34 - Hydrogen Auto Videos

Tuesday 27 February 2007 @ 6:31 pm

This test is one of two tests that will show how the plates react to a small plastic tube enclosure. The test is to determine if the space might have some play in the amount of current (amps) that are required to produce Hydrogen. The test is done using a 3 ½ by 19 inch plastic tube opened at both ends placed over 11 plates 3 by 5 ½ submerged in a 7 ½ square container. After the test ran it was noted that the water was clear without any discoloration. The second test in the next video will be made to test the volume of gas that is put out using this method.


, , , , , ,




Water Car - Hydrogen Auto Videos

Tuesday 27 February 2007 @ 6:13 am

A car that runs on water


, , , , , , ,




Hydrogen Tap 1 Series 3 (Hydrogen Separation Tower) #33 - Hydrogen Auto Videos

Monday 26 February 2007 @ 6:39 pm

This is the first test of the Series 3 unit that separates Hydrogen and Oxygen. This method has taken me many hours of sleepless nights to work out. There are many ways being used to separate Hydrogen and Oxygen but they cause the plates or electrodes to be spaced farther apart and making the use of electrolytes an important factor. This method keeps the plates as they are in the Series 2 system and allows the use of tap water without the electrolytes. I hope in publishing this I can further the cause that I am so devoted to and its simplicity of design makes it available for all to work add to the knowledge base. Please write me on any new systems that you have created using this design. John AArons


, , , , , , ,




Hydrogen Tap 1 (Testing 110 Volt System) #28 - Hydrogen Auto Videos

Monday 26 February 2007 @ 6:42 am

This is to show what a 110 volt system would look like. This test is made using two 5 ½ by 3 inch plates ½ in apart. The test was conducted using house 110 volt ac converted to 15 volts by using an AC to DC solid state converter. The test was don after I received many requests to see what 110 volt system would look like. I tried AC and found that at 60 cycles /2 the system would not work. The plates could not be moved closer together because the amps jumped over 30 and was uncontrollable.


, , , , , ,




Hydrogen Tap 1 Series 3(WHY IS WATER CLEAR) #36 - Hydrogen Auto Videos

Sunday 25 February 2007 @ 6:15 pm

This is a retest to see if more water would run in the unit without showing the discoloration that always shows up when we run current through water. In this test more tap water was taken from the same sink. This is the 2nd test (3rd video) using the tubes where for some reason the water stays clear. The test runs for nine minutes and confirms that the water in this unit stays clear. This is the final test before I test the amount of gas being produced by this unit.Could the answer be the enclosure?There is an interesting thing going on in the tube. The Hydrogen is being produced faster than it can escape in the air so it gets pushed to the bottom where it is forced between the plates. In effect the Hydrogen is being hit again with the power over and over again. This might bring down the amount of power (amps) we need to use.


, , , , , ,




Hydrogen Tap 1 Series 3 (Construction New Series 3) #37 - Hydrogen Auto Videos

Sunday 25 February 2007 @ 6:18 am

This video shows construction of the new Series 3. This unit will be used to test my ides about the relationship of the container with the amount of power required to run it. It is my idea that the “pulse systems” are using the tubes not the pulse to create more Hydrogen with less power (amps). In the last tests using the plastic tube I have noted a decrease in the amount of power needed to run the unit while the amount of Hydrogen “seems” to stay the same. One of the tests that will be conducted with this unit is to measure the output of the gas using the same method as in series 2.


, , , , , ,




Official Car Commercial - Hydrogen Auto Videos

Saturday 24 February 2007 @ 6:17 pm

The official car commercial for school.


, , , , , , ,




Hydrogen Tap 1 Series 2( Hot Cold Water LESS AMPS) # 22 - Hydrogen Auto Videos

Saturday 24 February 2007 @ 6:41 am

This test is being performed on the new 12 plate system. Each plate is being separated by two nonconductive washers hocked positive negative alternately. The test shows how putting the plates in “hot water” than in cold water lowers the amount of power (amps) required to run the unit. The plates are 5 ½ inch by 3 inches and the test is being run on one 12 volt battery.


, , , , , ,




«« Previous Posts